KDLS Series Evaporativa Condenser Venditio

Home / Products / Condensator Evaporatione Utens / KDLS Series Evaporativa Condenser
  • KDLS Series Evaporativa Condenser
  • KDLS Series Evaporativa Condenser
  • KDLS Series Evaporativa Condenser                       Zhejiang Kaidi Refrigeration Equipment Co., Ltd
  • KDLS Series Evaporativa Condenser                        Zhejiang Kaidi Refrigeration Equipment Co., Ltd

KDLS Series Evaporativa Condenser

Series KDLS evaporativarum condensantium solutiones refrigerationis efficientis efficit solutiones innovationis cum consilio et observantia superiori. Apparatus aqua et aere utitur ut medio, et refrigerans gaseum in liquorem condensat per singularem evaporationem caloris mechanismum commutantium. Coro eius componente, princeps efficientiae ellipticae spirae compositionem compactam adhibet, quae calor commutationem spatio per 20% ad fistulas circulares traditionales comparatas auget. Fit etiam cum scopulo consilio et processu icto, qui non solum impetum refrigerandi minuit, sed etiam pericula lacus a causa radice vitat; calidum-intinge cadmiae anti-corrosio et summus pressura testing ensure longum tempus et stabilis operatio.

CONTACT US
01 Commoda 02Specificationes 03Dimensiones 04Unitas Configurationis 05Interrogatio

In speciali consilio, apparatu praestantior est. Summus qualitas caloris PVC commutatio sarcina, independentia structura aeris cubiculi, corrosio repugnans archa et summus efficientia in unum opus ventilabrum directum connexum, quod non solum auget efficientiam commutationem caloris, sed etiam industriam consummationem et sustentationem gratuita minuit. Spatio systematis umbellae nozzles multi-circuli ad consequendum uniforme coverage, et innovationes ut anti-vortex aeris fenestras obliquas instruit et lacus aquae ad ulteriorem administrationem editi et aquae fluxus optimize. Sive in gravibus ambitus velitis sive missionibus industrialibus cum maximis requisitis ad efficientiam et stabilitatem, series KDLS certa refrigerationis subsidii praebere possunt..

01 Commoda

In speciali consilio, apparatu praestantior est. Summus qualitas caloris PVC commutatio sarcina, independentia structura aeris cubiculi, corrosio repugnans archa et summus efficientia in unum opus ventilabrum directum connexum, quod non solum auget efficientiam commutationem caloris, sed etiam industriam consummationem et sustentationem gratuita minuit. Spatio systematis umbellae nozzles multi-circuli ad consequendum uniforme coverage, et innovationes ut anti-vortex aeris fenestras obliquas instruit et lacus aquae ad ulteriorem administrationem editi et aquae fluxus optimize. Sive in gravibus ambitus velitis sive missionibus industrialibus cum maximis requisitis ad efficientiam et stabilitatem, series KDLS certa refrigerationis subsidii praebere possunt..

02Specificationes

Calor reprobatio mensae coefficiens

A: Refrigerant R717 (Ammonia) Caloris Dissipation Correctio Factor Table
Condensatio temperatus
(℃)
Aeris humidum bulbus temperatus (℃)
13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
29 0.83 0.87 0.92 0.97 1.04 1.10 1.19 1.30 1.43 1.60 1.83 2.15 2.64 / / / / /
30 0.78 0.82 0.86 0.90 0.96 1.01 1.09 1.18 1.28 1.42 1.60 1.84 2.19 2.62 / / / /
31 0.73 0.76 0.80 0.83 0.88 0.92 0.98 1.05 1.13 1.23 1.36 1.52 1.74 2.05 2.45 / / /
32 0.69 0.72 0.75 0.78 0.82 0.86 0.91 0.97 1.03 1.12 1.22 1.35 1.52 1.75 2.06 / / /
33 0.65 0.67 0.70 0.72 0.76 0.79 0.83 0.88 0.93 1.00 1.08 1.17 1.29 1.45 1.70 1.95 2.26 2.64
34 0.62 0.64 0.66 0.68 0.71 0.74 0.78 0.82 0.86 0.92 0.99 1.06 1.16 1.29 1.48 1.67 1.93 2.21
35 0.58 0.60 0.62 0.64 0.67 0.69 0.72 0.75 0.79 0.84 0.89 0.95 1.03 1.12 1.25 1.38 1.56 1.74
36 0.55 0.57 0.59 0.61 0.63 0.65 0.68 0.71 0.74 0.78 0.82 0.88 0.94 1.02 1.12 1.23 1.37 1.52
37 0.53 0.54 0.56 0.57 0.59 0.61 0.63 0.66 0.69 0.72 0.75 0.80 0.85 0.91 0.99 1.07 1.18 1.30
38 0.50 0.52 0.53 0.55 0.56 0.58 0.60 0.62 0.65 0.68 0.70 0.75 0.79 0.84 0.90 0.97 1.05 1.14
39 0.48 0.49 0.51 0.52 0.54 0.55 0.56 0.58 0.60 0.63 0.65 0.69 0.72 0.76 0.82 0.87 0.95 1.02
40 0.46 0.47 0.48 0.50 0.51 0.52 0.54 0.55 0.57 0.60 0.62 0.65 0.68 0.71 0.76 0.80 0.86 0.93
41 0.44 0.45 0.46 0.47 0.48 0.49 0.51 0.52 0.54 0.56 0.58 0.60 0.63 0.66 0.70 0.73 0.78 0.82
42 0.42 0.43 0.44 0.45 0.46 0.47 0.49 0.50 0.51 0.53 0.55 0.57 0.59 0.62 0.65 0.68 0.72 0.76
43 0.41 0.41 0.42 0.43 0.44 0.45 0.46 0.47 0.48 0.50 0.52 0.53 0.55 0.57 0.60 0.63 0.67 0.70
44 0.39 0.40 0.41 0.42 0.42 0.43 0.44 0.45 0.46 0.48 0.49 0.51 0.52 0.54 0.57 0.59 0.62 0.66
45 0.38 0.38 0.39 0.40 0.41 0.41 0.42 0.43 0.44 0.45 0.46 0.48 0.49 0.51 0.53 0.55 0.58 0.61
B: Refrigerant R22, R134a (Freon) calor rejectionis correctionis mensae coefficientis
Condensatio temperatus
(℃)
Aeris humidum bulbus temperatus (℃)
13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
29 1.00 1.04 1.10 1.16 1.24 1.32 1.43 1.56 1.73 1.94 2.22 2.62 3.21 / / / / /
30 0.94 0.98 1.03 1.08 1.15 1.22 1.31 1.42 1.55 1.72 1.94 2.24 2.67 3.09 / / / /
31 0.88 0.91 0.96 1.00 1.06 1.11 1.18 1.27 1.37 1.50 1.65 1.86 2.13 2.51 / / / /
32 0.83 0.86 0.90 0.94 0.98 1.03 1.10 1.17 1.25 1.36 1.48 1.65 1.86 2.15 2.51 / / /
33 0.78 0.80 0.84 0.87 0.91 0.95 1.01 1.06 1.13 1.22 1.31 1.43 1.59 1.78 2.09 2.40 2.78 3.27
34 0.74 0.76 0.79 0.82 0.86 0.90 0.94 0.99 1.05 1.12 1.20 1.30 1.43 1.58 1.82 2.06 2.38 2.80
35 0.70 0.72 0.75 0.77 0.81 0.84 0.87 0.92 0.96 1.02 1.09 1.17 1.26 1.38 1.55 1.71 1.98 2.33
36 0.67 0.69 0.71 0.73 0.76 0.79 0.82 0.86 0.90 0.95 0.96 1.08 1.15 1.25 1.38 1.52 1.71 1.98
37 0.64 0.65 0.67 0.69 0.72 0.74 0.77 0.80 0.84 0.88 0.83 0.98 1.04 1.12 1.22 1.32 1.45 1.63
38 0.61 0.63 0.64 0.66 0.68 0.71 0.73 0.76 0.79 0.83 0.82 0.92 0.97 1.03 1.12 1.20 1.32 1.43
39 0.59 0.60 0.62 0.63 0.65 0.67 0.69 0.71 0.74 0.77 0.81 0.85 0.89 0.94 1.01 1.08 1.17 1.27
40 0.56 0.58 0.59 0.60 0.62 0.64 0.66 0.68 0.70 0.73 0.76 0.80 0.84 0.88 0.94 1.00 1.07 1.15
41 0.54 0.55 0.56 0.57 0.59 0.60 0.62 0.64 0.66 0.69 0.71 0.74 0.78 0.81 0.86 0.91 0.97 1.03
42 0.52 0.53 0.54 0.55 0.56 0.58 0.60 0.61 0.63 0.66 0.68 0.70 0.74 0.76 0.80 0.85 0.90 0.95
43 0.50 0.51 0.52 0.53 0.54 0.55 0.57 0.58 0.60 0.62 0.64 0.66 0.69 0.71 0.75 0.78 0.83 0.86
44 0.48 0.49 0.50 0.51 0.52 0.53 0.55 0.56 0.58 0.59 0.61 0.63 0.65 0.68 0.71 0.74 0.78 0.81
45 0.46 0.47 0.48 0.49 0.50 0.51 0.52 0.53 0.55 0.56 0.58 0.59 0.61 0.64 0.67 0.69 0.73 0.77

Exemplar List

KDLS series evaporative condenser exemplar album
Vide numerum nomen codice Calor output (KW) Vide numerum nomen codice Calor output (KW)
1 KDLS-300 300 22 KDLS-1600 1600
2 KDLS-340 340 23 KDLS-1720 1720
3 KDLS-370 370 24 KDLS-1800 1800
4 KDLS-390 390 25 KDLS-1900 1900
5 KDLS-420 420 26 KDLS-2090 2090
6 KDLS-450 450 27 KDLS-2200 2200
7 KDLS-480 480 28 KDLS-2340 2340
8 KDLS-550 550 29 KDLS-2400 2400
9 KDLS-660 660 30 KDLS-2580 2580
10 KDLS-700 700 31 KDLS-2700 2700
11 KDLS-730 730 32 KDLS-2850 2850
12 KDLS-780 780 33 KDLS-3000 3000
13 KDLS-800 800 34 KDLS-3200 3200
14 KDLS-860 860 35 KDLS-3440 3440
15 KDLS-900 900 36 KDLS-3600 3600
16 KDLS-950 950 37 KDLS-3800 3800
17 KDLS-100 1100 38 KDLS-4050 4050
18 KDLS-1320 1320 39 KDLS-4300 4300
19 KDLS-1400 1400 40 KDLS-4600 4600
20 KDLS-1460 1460 41 KDLS-4900 4900
21 KDLS-1560 1560

KDLS series mensae parametri condensantis evaporativae

Parameter Tabula Standard
Caloris officii sint
KW
Dimensiones Axialis fluxus fans Sentinam aqua imbre Apparatus
Pondus
kg
Operans pondus kg R717
Crimen
kg
Pipe parametri (mm) Electric heating power (kW)
Longitudo (mm) latitudo mm summus
mm
Potestas
KW
Nominal aeris volumen m3/h Potestas
KW
Influunt rate
m³/h
Aestuosus et exitus fistula diameter Aqua replenishment / purgamentorum missionem / inundationem -15℃ -25℃
KDLS-300 300 1990 2530 4060 3×1 42000×1 1.5×1 60×1 2523 3918 31 1-DN100
1-DN100
1-DN25
1-DN50
1-DN80
1×4 1×6
KDLS-340 340 4060 4×1 49500×1 2533 3928 31
KDLS-370 370 4060 5.5×1 61000×1 2543 3938 31
KDLS-390 390 4060 4×1 49500×1 2717 4112 42
KDLS-420 420 4060 5.5×1 61000×1 2727 4122 42
KDLS-450 450 4060 4×1 49500×1 2912 4307 52
KDLS-480 480 4060 5.5×1 61000×1 2932 4327 52
KDLS-550 550 1990 3130 4810 7.5×1 86000×1 2.2×1 130×1 3408 5427 54 1-DN100
1-DN100
1-DN25
1-DN50
1-DN80
1×4 1×8
KDLS-660 660 4810 5.5×1 830001 3617 5636 68
KDLS-700 700 4810 7.5×1 86000×1 3647 5666 68
KDLS-730 730 4810 7.5×1 86000×1 3886 5905 76
KDLS-780 780 4810 11×1 97000×1 3927 5946 76
KDLS-800 800 1990 3500 4810 7.5×1 93000×1 2.2×1 130×1 4071 6395 81 1-DN100
1-DN100
1-DN25
1-DN50
1-DN80
1×6 1×10
KDLS-860 860 4810 11×1 105000×1 4111 6435 81
KDLS-900 900 4810 7.5×1 93000×1 4357 6681 98
KDLS-950 950 4810 11×1 105000×1 4397 6721 98
KDLS-100 1100 3902 3130 4830 7.5×2 86000×2 4×1 1701 5888 9682 110 1-DN100
1-DN100
1-DN25
1-DN50
1-DN80
1×8 1×12
KDLS-1320 1320 4830 7.5×2 86000×2 6362 10156 137
KDLS-1400 1400 4830 11×2 97000×2 6442 10236 137
KDLS-1460 1460 4830 7.5×2 86000×2 6835 10629 164
KDLS-1560 1560 4830 11×2 97000×2 6915 10709 164
KDLS-1600 1600 3902 3500 4830 7.5×2 93000×2 4×1 1701 6984 11389 164 2-DN100
2-DN100
1-DN25
1-DN50
1-DN80
1×12 1×18
KDLS-1720 1720 4830 11×2 105000×2 7064 11469 164
KDLS-1800 1800 4830 7.5×2 93000×2 7660 12065 197
KDLS-1900 1900 4830 11×2 105000×2 7740 12145 197
KDLS-2090 2090 5814 3130 4850 7.5×3 86000×3 5.5×1 240×1 9533 15185 206 2-DN100
2-DN100
1-DN25
2-DN50
1-DN80
1×12 1×16
KDLS-2200 2200 4850 7.5×3 86000×3 10260 15912 248
KDLS-2340 2340 4850 11×3 97000×3 10380 16032 248
KDLS-2400 2400 5814 3500 4850 7.5×3 93000×3 7.5×1 270×1 10652 17304 248 2-DN100
2-DN100
1-DN25
2-DN50
1-DN80
1×12 1×18
KDLS-2580 2580 4850 11×3 105000×3 10771 17423 248
KDLS-2700 2700 4850 7.5×3 93000×3 11521 18173 297
KDLS-2850 2850 4850 11×3 105000×3 11641 18293 297
KDLS-3000 3000 7726 3500 4870 5.5×4 770004 4×2 1702 13657 22000 325 2-DN100
2-DN100
2-DN25
2-DN50
1-DN80
2×8 2×12
KDLS-3200 3200 4870 7.5×4 93000×4 13737 22080 325
KDLS-3440 3440 4870 11/4 105000×4 13897 22240 325
KDLS-3600 3600 4870 7.5×4 93000×4 14861 23204 391
KDLS-3800 3800 4870 11/4 105000×4 15021 23364 391
KDLS-4050 4050 5120 11/4 105000×4 16312 24655 456
KDLS-4300 4300 8990 3500 4870 7.5×4 93000×4 5.5×2 240×2 16906 26746 457 2-DN100
2-DN100
2-DN25
2-DN50
1-DN80
2×10 2×12
KDLS-4600 4600 4870 11/4 105000×4 17068 26908 457
KDLS-4900 4900 5120 11/4 105000×4 18583 28423 533
03Dimensiones
  • 04Unitas Configurationis
    Fabrica Model Magnitudo (mm) Numerus laminarum ferro embedded
    L W A B*n
    KDLS300~480 1990 2530 1240 1500x1 4-300x300
    KDLS550~780 1990 3130 1540 1500x1 4-300x300
    KDLS800~950 1990 3500 1725 1500x1 4-300x300
    KDLS1100~1560 3902 3130 1540 1500x2 6-300x300
    KDLS1600~1900 3902 3500 1725 1500x2 6-300x300
    KDLS2090~2340 5814 3130 1540 1500x3 8-300x300
    KDLS2400~2850 5814 3500 1725 1500x3 8-300x300
    KDLS3000~4050 7726 3500 1725 2200x3 8-300x300
    KDLS4300~4900 8990 3500 1725 1500x4

    10-300x300

    Technica descriptio:
    (1) Concretum (vel chalybe) subsidia et immersa partes ab usuario praebebuntur. Consilium sistens fabrum professionalium perficietur ut fundationis instrumenta tuta sint.
    (2) Fundamentum onus computabitur ad pondus operantem instrumenti, et fundamenta quantitatis secundum magnitudinem tabulae comparationis funda- buntur.
    (3) Superior superficies subsidii concreti (vel chalybis) plana esse debet, et planities 1.5mm per metrum non excedere.
    (4) In institutione, gaskets inter sustentationem et apparatum aequandi uti non licet.
    (5) Praeter systematis nexum occurrentem altitudo requisita, altitudo concreti (vel chalybis) firmamentum non minus quam 800mm e terra ad imum apparatum sustentationem faciliorem reddet. Priusquam apparatum inaugurari oporteat, instrumentum manuale diligenter legetur et institutionis requisita ibi sequenda sunt.
    (VI) Propositum apparatum peragi debet secundum electionem suasiones. Nulla impedimenta vel impedimenta circa apparatum aeris limbi cratis et axialis faunum exitum exhauriant..

    05Interrogatio

    Zhejiang Kaidi Refrigeration Equipment Co., Ltd

    • 30+

      Anni Experientiae Industriae

    • 300+

      Operarii

    • 1000Decies Centena Milia

      Summa Exportationis

    • 100000+

      Area Plantationis

    Zhejiang Kaidi Refrigeration Equipment Co., Ltd. condita est anno 1995, cum “Kaidi” ut nostra nota registrata. Ut una ex professionalibus Sina KDLS Series Evaporativa Condenser Suppletor et Venditio KDLS Series Evaporativa CondenserOEM/ODM Societas, nos in refrigeratione per fere 30 annos versati sumus. Hodie, Kaidi in scientificam et technologicam societatem evoluta est quae scientificam investigationem et evolutionem, processum et fabricationem, consilium programmatis ante venditionem, venditionem productorum et probationem, et comprehensivam post-venditionem servitii sustentationem integrat. Caput in urbe Shengzhou, provincia Zhejiang, nostra fabrica aream 100,000 metrorum quadratorum occupat, cum plus quam 60,000 metris quadratis aedificiorum modernorum fabricae et plus quam 8,000 metris quadratis officiorum, necnon Officio Shanghai Hongqiao (Centrum Investigationis et Evolutionis), Officio Guangzhou Panyu, Rami Beijing et sic porro.

    Post annos evolutionis, turmam administrationis societatis summae 500 et systema operationis normatum et efficax habemus, necnon validam vim investigationis et evolutionis technicae. Fabrica instructa est instrumentis machinationis CNC completis et provectis et laboratorio probationis altae normae, cum validis facultatibus evolutionis productorum et processuum fabricationis tenuium; institutio professionalis sustentationis technicae ante venditionem, systematis cautionis post-venditionem, non solum investigationem et evolutionem et productionem instrumentorum refrigerationis provectarum facimus, sed etiam provisor solutionis totius pro clientibus altae qualitatis ut productos et servitia primae classis praebeamus ad propositum et finem nostrum confirmandum.

    Nostra retis venditionis et servitii non solum per totam terram diffunditur, sed etiam in mundo his paucis annis celeriter crescit; producta refrigerationis notae ‘Kaideli’ magnam famam domi forisque habent, et laudem et recognitionem clientium nostrorum meruerunt. Nunc clientes nostri includunt: societates logisticae catenae frigidae ut GLP, Shunfeng, Jingdong, Yaleng, Kai Orange, etc.; societates processus ciborum ut Wufeng, Holliday, Ligao, Qingmei, Zuming, Anjing, Sienian, etc., coquinae centrales ut Makgindi, Lvcheng, Ajisai, etc.; societates caedis ut Winsome, Xinning, etc.; societates plantationis fungorum edulium in officinis ut Xiangru Biological, Guiwang, Huaguang, Zongxing Mushroom, Lisa, etc., necnon Shanghai Pharmaceuticals, China Medicine Group, et sic porro. Group et sic porro.

    HONOR ET CERTIFICATUM

    Producta nostra obtinuerunt, includunt Certificatum Examinationis EC-Type, BV, MODE, DNV, Certificatum GL, Attestationem Conformitatis EC, Certificatum Approbationis Typi pro Producto Maritimo et Lloyd’s Register Quality Assurance.

    • Certificatorium conformitatis aestimatio experimentorum adinventiones
    • Specialis Equipment Vestibulum License
    • Boletus edulis Enterprise vestibulum stella
    • Praeclara Unitas Sodalis Sinensis Instituti Refrigerationis
    • 2023 Guangxi Refrigeratio Societas Refrigeratio et Frigus PRAECLUSIO Committee Specialioribus
    • Scientia et ars Achievement aestimatione certificatorium
    • Scientia et ars Achievement aestimatione certificatorium
    • Scientia et ars Achievement aestimatione certificatorium
    • Scientia et ars Achievement aestimatione certificatorium
    • Scientia et ars Achievement aestimatione certificatorium
    • Scientia et ars Achievement aestimatione certificatorium
    • Scientia et ars Achievement aestimatione certificatorium
    • Scientia et ars Achievement aestimatione certificatorium
    • Scientia et ars Achievement aestimatione certificatorium
    • Scientia et ars Achievement aestimatione certificatorium
    • Scientia et ars Achievement aestimatione certificatorium
    • Scientia et ars Achievement aestimatione certificatorium
    • Computer Software Copyright Registration Quisque
    • Computer Software Copyright Registration Quisque
    • Computer Software Copyright Registration Quisque
    Nuper Nuntii et Eventus
    Tecum communicare
    Plures Nuntios Videre

    MITTE NUNTIUM

    Nuntius relinquere tuum ****

    FAQ

    • Q. Quam mox responsum accipere possumus postquam te Inquisitionem mittimus?

      Respondebimus tibi intra XXIV horas post inquisitionem in diebus ferialibus.
    • Q. Quam multi Employees tuus Factory Have?

      Societas currently plus quam trecentos operarios habet, in quibus plus quam centum personas professionales et technicas.

    • Q. How Does Your Company Perficite Product Quality?

      Primo, post singulas processus inspectiones. Ad extremum productum, plenam inspectionem secundum exigentias mos et signa internationalia peragimus